Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13712191
- Product Categories
- Friendly Links
- home > Supply > Floor drain factory direct side row floor drain to drain straight-threaded cast iron floor drain to drain various models of quality assurance
Floor drain factory direct side row floor drain to drain straight-threaded cast iron floor drain to drain various models of quality assurance
Information Name: | Floor drain factory direct side row floor drain to drain straight-threaded cast iron floor drain to drain various models of quality assurance |
Published: | 2015-04-30 |
Validity: | 60000 |
Specifications: | DN100 |
Quantity: | 1.00 |
Price Description: | |
Detailed Product Description: | 1 floor drain, is an important interface to connect the sewer system and the interior surface of housing as an important component in the drainage system, its performance directly affects the quality of indoor air is very important for the bathroom odor control. 2 floor drain to drain into straight free formula and deodorant formula. Introduction to drain dìlòu 1, the English name: floor drain 2, ground floor drain is draining appliances and drains connected to the system. 3, floor drain is special: it eliminates the surface water, water quality is worse than any other appliance, solids, fibers, and more hair, easy sediments. 4, People's Republic of China National Standard GB50015-2003 "building water supply and drainage design specifications" 4.5.10 excerpt floor drain should be chosen to meet the following requirements: 1 should give priority to floor drain odor. Provisions Note: 4.5.10 According to the survey, Bell floor drain, there is a seal shallow bowl buckle easily throw away the drawbacks, many hotels, hotels, residential buildings and other residential and public bathrooms, floor drain into a vent hole, harmful gases in the sewers of fleeing indoor pollution indoor environmental health. Self-styled floor drain with a magnet, such as the principle of spring seem novel, but the general effect, because the bathroom drainage, poor water quality, it is not effective deodorant, is not recommended for home use 5. drainage Building Code Chapter 18 drain G2010-040 6, the main drain Function: Anti-odor, anti-blocking, anti-cockroach, anti-virus, anti-back water, anti-dry 3 Cognitive floor drain floor drain should have four properties: fast drainage, anti-odor, anti-jam-free cleaning. Floor drain, floor drain, as the name suggests is to drain, single-function floor drain drain only been behind the times. Not only to drain the water fast, the most important thing is to anti-clogging, otherwise too old to clean up, it is a recipe for disaster. Now on the market a variety of floor drain variety, price from 3-5 yuan to 100 yuan range, but can really play deodorant effect on hard to find, they say this is the deodorant floor drain, the effect can be used only until you After spend will know. 4 choice points 1), CJ / T 186-2003 standard applies only to general industrial and civil buildings used to leak, does not apply to special places such as civil air defense works for the breakwater floor drain, petrochemical enterprise-specific proof floor drain. For a special place in the floor drain, in addition to refer to this standard, it must also meet the technical requirements of the relevant industries. 2), the seal is one of the important features are seal floor drain. Selection should understand the depth of water seal products has reached 50mm. Sidewall floor drain, floor drain with a network box, closed-type floor drain without a water seal most general; spill drain, multi-channel to drain most of the band seal, should be selected according to the manufacturer specific data understood. For without water seal floor drain, floor drain outlet pipe should be equipped with water seal depth of not less than 50mm trap. This component can be configured to drain manufacturer, or set by the installation of the construction unit to drain. 3), floor drain grates surface height can be adjusted to regulate the height of not less than 35mm, to ensure that the floor drain surface elevation and ground floor flat after the renovations are completed. Floor drain fortification hydrofoil ring is to do the floor drain installed in the floor of the water requirements. Located in the Underground Garage channel or bear a load of places to leak, it grates should be able to meet the corresponding load strength. 4), floor drain with a water seal structure to be reasonable, smooth, draining the debris is not easy to settle down; cross section area should be greater than the cross-sectional area of ??each part of the exhaust pipe, and the flow channel cross-section of minimum clear width of not less than 10mm. 5), floor drain connected in three ways: socket; thread; clamps. Connector size according to the relevant provisions in the state for 6), should give priority to floor drain odor. Not need draining place, you can not set the floor drain. Builders have not set back left to drain inlets shall be completed. 5 beautify the dry zone of the floor drain may be provided in an inconspicuous position, because the ground will not have too much water; and wet area, such as shower areas, in order to ensure smooth water, so not only can not be hidden below ground have it about 10mm, might not look good. In this case, it can be decorated by some of the design. For example, the floor drain hide, do the above a floating hollow metal decoration, and it resonates with the interior effect, can also play a "second filter" role. Alternatively, you can drain the surrounding ground with mosaic paving the curved, sloping design, so the shape of both beautiful and it helps to speed up the water flow rate. Alternatively, you can take advantage of the characteristics of the bathroom floor is padded to drain as the center to make a small "pond." 6 install floor drain installation is relatively complex and must be done by the professionals. When the installation should pay attention to: replace the floor drain to tear down the original floor drain to avoid digging through brick waterproof layer of cement to avoid damage, install floor drain to avoid debris clogged sewer drains off. Install floor drain as much as possible to avoid the use of cement and other materials, such as plastic glass because fixed bad. 7 floor drain main material mainly cast iron, PVC, aluminum, stainless steel, brass, copper alloys and other materials. 1, cast iron: cheap, easy to rust, unsightly, rust after hanging sticky dirt, easy to clean; 2, PVC: cheap, easily influenced by temperature deformation, poor scratch resistance and impact resistance, unsightly ; 3, aluminum: mid-range price, light weight, is rough; 4, Stainless Steel: affordable, beautiful and durable; 5, copper alloys: affordable, practical. 6, Brass: heavy quality, high-grade, high price, do the plating surface. 8 floor drain - Maintenance 8.1 drain pan taste Analysis: may be high enough to drain the water seal, easily dry up, resulting in the sewer stench inside the pan into the room. Solution: First, do not necessarily have to drain the water back bend, plus a go in to; second, for a same brand, same size of the floor drain. But construction, be careful not to damage the waterproof layer. In addition, to be reminded that, in use, it should prevent seal dry, subject to regular water. If the long-term leave, preferably with a lid to drain sealed. 8.2 floor drain overflow Cause Analysis: It may be the floor drain cross section is not smooth, sewage can not be quickly adopted, or floor drain because the internal structure of male and female, all tangled up in the hair, fibers and other kind of dirt. Workaround: floor drain piping height is determined by way of the drainage system. Therefore, the choice of accompanying drain height is preferably less than 200mm respectively and within 120mm, and must be lateral drainage. Common practices of concealed structural floor bathroom sink local piping and toilet cushion tube made of two fabrics. In order to meet the requirements of toilet clear height and ergonomic, the former sink clearance is 300mm, which cushion height up to 170mm 8.3 to drain seepage Solution: The floor drain tiles around the open, surrounded by cement dug 3cm deep, then with "plugging Ling" seal it, one hour after doing closed water test to see if it has water seepage, such as not seeped it means restitution. |
Admin>>>
You are the 6340 visitor
Copyright © GuangDong ICP No. 10089450, Power Parts Co., Ltd. Changzhou Yongsheng All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 6340 visitor
Copyright © GuangDong ICP No. 10089450, Power Parts Co., Ltd. Changzhou Yongsheng All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility